Hazardous Location LED Lighting
Hazardous Location LED Lighting
MODEL L1403AS · THT-EX Series
Floodlight-style luminaire for IIC hazardous area applications, available in single and dual-lamp (80W) configurations. Ex nR IIC T5 Gc and Ex tb IIIC T100°C Db certified under IEC/EN 60079 standards. Aluminum alloy enclosure with PC cover, IP67 & NEMA 6 rated, and 60,000-hour LED service life.
65-95W
Power Range
IP67
Protection
60K
Service Hrs
9500lm
Max Lumen
Certifications:
2Zone
21Zone
22Zone
IP67
NEMA 6
Protection & Standards
Explosion-protection markings & compliance
Protection
Ex nR IIC T5 Gc
Ex tb IIIC T100°C Db
II 3 G Ex nR IIC T5 Gc
II 2 D Ex tb IIIC T100°C Db
Standards
IEC 60079-0
IEC 60079-15
IEC 60079-31
EN 60079-0
EN 60079-15
EN 60079-31
Technical Data
Full specification
| Model | L1403AS | |||||||||||||||
| Rated Voltage (±10%) | 110V / 220V / 277V AC | |||||||||||||||
| Watts (±10%) | 65W / 75W / 80W / 95W | |||||||||||||||
| Amps |
65W — 110V: 0.59A, 220V: 0.30A, 277V: 0.23A 75W — 110V: 0.68A, 220V: 0.34A, 277V: 0.27A 80W — 110V: 0.73A, 220V: 0.36A, 277V: 0.29A 95W — 110V: 0.86A, 220V: 0.43A, 277V: 0.34A |
|||||||||||||||
| Color of LED Light | 3000K (Warm White) / 5000K (Cool White) | |||||||||||||||
| Ambient Temperature | -25°C ~ +55°C, T5 | |||||||||||||||
| Power Factor | cos ≧ 0.9 | |||||||||||||||
| CRI | Cool White ≧ 70 | Warm White ≧ 80 | |||||||||||||||
| Lumen (±10%) |
|
|||||||||||||||
| Beam Angle | X-116° / Y-115° | |||||||||||||||
| Frequency | 50 / 60 Hz | |||||||||||||||
| Degree of Protection | IP67 / NEMA 6 | |||||||||||||||
| Material — Enclosure | Aluminum Alloy | |||||||||||||||
| Material — Cover | PC Cover | |||||||||||||||
| LED Service Life | 60,000 hrs | |||||||||||||||
| Entrance Thread | 1 × M25 | |||||||||||||||
| Net Weight | 5.0 kg (11.0 lb) |
Dimensions
Millimeters (inches) · Single-Lamp Floodlight
Length
300.0 mm (11.81 in)
Width
220.0 mm (8.66 in)
Height
132.0 mm (5.2 in)
Net Weight
5.0 kg (11.0 lb)